MIDAS for engineering

A process simulator that
knows your plant.

A process simulator, design and specification tool, with the plant’s own design basis behind it. The design calculations, on demand, at today’s conditions, with every source visible.

What MIDAS does for engineers

  • Re-runs the design calculations at today’s conditions, so you see what each piece of equipment should be doing right now, next to what it is doing.
  • Works design-first: any calculation on a plant stream, a stream from your library, or a new one; on plant equipment or a design that does not exist yet.
  • Deterministic and traceable: same inputs, same answer, every time. Every number carries its method and source, and the language model never produces one. Checked against published data and an actual plant’s simulation cases; differences are reported, never tuned away.
  • Answers outside a method’s range, and says so: you still get the result, with a warning naming the range. A unit past a physical limit, such as critical heat flux, is still rated, with the warning leading the answer.
Calculation coverage

The equipment of a gas plant.

Phase behavior

Two- and three-phase flash, dew and bubble point, true vapor pressure, on twelve thermodynamic models including Peng-Robinson, SRK and CPA for water and glycols. Hydrates, and the methanol or MEG to prevent them.

Equipment

Separators with mist pads and partial volumes; equilibrium and rate-based columns with tray and packing hydraulics; shell-and-tube, kettle, thermosyphon and air-cooler rating against the vendor’s guaranteed case; brazed-aluminium plate-fin cores; fired heaters; amine treating, including piperazine-activated MDEA; mol sieve and carbon beds.

Water and corrosion

pH of water phases at line and sample conditions, including brines and sour water; CO2 corrosion rate of carbon steel.

Rotating, relief and lines

Compressors, expanders, multistage trains, refrigeration loops, pumps and drivers; relief valve sizing to API 520, 521 and 526 and a full overpressure scenario study; flare and vent dispersion; line sizing to API RP 14E and ASME B31.3; flange ratings checked to ASME B16.5.

Flowsheets you draw and solve

Draw it. Execute it.

  • Drag blocks onto a canvas, connect them port to port and solve from the drawing. One Execute menu: the whole flowsheet, the selected block, or everything up to it. A re-run solves only what changed.
  • A Recycle block marks where a loop is cut. Every block warns when an inlet arrives below its pressure. Tidy the drawing routes every line clear, with one-step Undo.
  • Over thirty worked examples ship with it, including a complete amine loop.

Illustrative flowsheet.

SeparatorExchangerCompressorColumnCooler RECYCLE ▶ Execute ▾flowsheet · block · up to
CAL LOG ? nightshift change
■ normal band■ calibration■ logbook● MIDAS noticed
Performance from the plant’s own history

A fouling exchanger, or a drifting meter?

  • Exchanger U and fouling against MIDAS’s own clean rating at each day’s actual flows; mass balance at every metered node; how far to trust each instrument, from its calibration record. Each is judged against its measurement uncertainty, with ambient accounted for.
  • A measured U above the clean rating is never shown as a negative fouling factor; MIDAS asks why, instrument first.
  • The troubleshooting screen: several instruments on one chart inside their normal bands, with calibrations, logbook entries and shift changes on the timeline. Compare periods, cross-plot two instruments, trend exchanger and balance figures, or see a distribution against normal. Export, save, or hand it to Ask.

Illustrative chart. Validated on development data; live when connected to the historian.

Ask in words, or take exact control
  • “List the vessels” returns the tags and a downloadable table of design data with sources; asking what one item is returns its design data, lines, instruments and relief valves.
  • Ask for the task in ordinary words and MIDAS asks for each input in order, with a read-back before every run. Nothing is defaulted. Every capability is also a command, and gives the same number either way.
Coming next
  • What-if advice from a solved model of your own plant: “should I raise reflux?” answered as options with their predicted effect, never as orders.
  • Specification sheets and re-runnable case files in your own format.
  • Two-phase relief sizing.
Talk to us

See what MIDAS would do for your plant.

Ask for a walkthrough, the MIDAS documents for your role, or a conversation about your plant. Every installation is built on that plant's own records, so the first step is a conversation.

Or email info@midas-eng.com.